PREPARATION FOR SERVICING
How to use the Servicing Fixture 1. Unplug the connector CP301, CP353, CP810, CP820, CP850 and CP005, then remove the VCR Block from the set. 2. Connect as shown in the below figure using the Service Fixture. � Connect the Syscon PCB to the Main PCB with the cable JG162A and JG162H. � Connect the Syscon PCB to the CRT PCB with the cable JG162Y. 3. Short circuit between TP1001 and Ground with the cable JG154. (Refer to MAJOR COMPONENTS LOCATION GUIDE) The EOT, BOT and Reel Sensor do not work at this moment. 4. At that time, the STOP/EJECT button is available to insert and eject the Cassette Tape.
Head Amp PCB JG162A CP810
IF PCB Deck Chassis
Operation 1 PCB JG162H To Main PCB (CD810) CP850 To Main PCB (CD820) JG162Y CP820 TP1001 Syscon PCB