Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 6026 visitantes online.
Productos
Información
Destacado
Inicio >> PIONEER >> DEH-P40MP/XP/EW5 Manual de Servicio
 
 0 artículo(s) en Su carrito 

PIONEER DEH-P40MP/XP/EW5
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del PIONEER DEH-P40MP/XP/EW5 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
1

2

3

4

1.3.8 Coefficient display of adjustment results
For some of the adjustments (FE and RF offset, FZD cancel, F and T gains, and RFAGC), the adjustment results can be displayed and confirmed in the test mode. The coefficient display in each auto adjustment is as follows: 1) FE and RF offset Reference value = 32 (coefficient of 32 indicates that no adjustment is required) The value is displayed in the unit of approximately 32 mV. Ex. When the FE offset coefficient is 35, 35 - 32 = 3 x 32 mV = 96 mV The correction is about +96 mV, which means the FE offset before adjustment is - 96 mV. 2) F and T gain adjustment Reference value for focus and tracking = 20
B

A

The displayed coefficient / the reference value indicates the adjusted gain. Ex. When the AGC coefficient is 40, adjustment of 40 / 20 = 2 times (+ 6 dB) has been performed. (It means that the original loop gain was half the target, and the whole gain was doubled to obtain the target value.) 3) RF level adjustment (RFAGC) Reference value = 8 The coefficient of 9 to 15 indicates to increase the RF level (for more gains). The coefficient of 7 to 10 indicates to decrease the RF level

C

(for less gains). When the coefficient changes by 1, the gain changes by 0.7 to 1 dB. When the coefficient is 15, the gain is the maximum at TYP + 7.9 dB. When the coefficient is 0, the gain is the minimum at TYP - 4.6 dB.

D

E

F

16

CX-3195
1 2 3 4

Quizás también quiera comprar

$4.99

DEH-P40MP/XP/EW5 PIONEER
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.143 - Number of Queries: 104 - Query Time: 0.038