|
Usuarios conectados
Actualmente hay 6043 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
INC
JAA77451-R.3512.A
� Unlock the holder-moving lever, and move the holder down slowly by the lever. Insert the 3 alignment screwdrivers (long, middle, short) in the loosened screw holes of the rear lens chamber. Note) Because the screws cannot be seen, when inserting the alignment screwdrivers, put them straight down in the screw holes so that the screws can be easily found.
� Turn the power of the Monitor, LINE GENERATOR, and MEGALIGHT 100 to ON. By checking the screen of the Monitor, rotate the micrometers (X and Y) so that the intersection point of the cross lines*1 (calibrated) comes in the center of the Monitor. *1 Adjust the cross lines by turning the "LIGHT CONT." knob of "MEGALIGHT 100" and the focus ring until the calibration of the cross lines can be seen clearly.
Focus ring Cross line Note) In case the cross lines are tilted, adjust them by turning the chart, which is screwed in the rear tube of the equipment.
LIGHT CONT. knob
� When the intersection point of the cross lines comes in the center, tighten the 3 screws of the rear lens chamber with the alignment screwdrivers. Note) When the holder is raised, the intersection point of the cross lines is misaligned. So make an adjustment by considering this. � Move the holder-moving lever up slowly to lock the holder, and remove the lens from the equipment (for periphery).
Added page
- A16-5ï½¥ AF24-85/2.8-4D -
February. 14. 2005
|
|
|
> |
|