6. ADJUSTMENT
6.1 IDLE CURRENT ADJUSTMENT
¶ CAUTION : Heatsinks� (Q323�Q326) DC level is equal to +B or -B. Don�t touch them or you will be electric shocked. 1. Connect the measuring instrument as shown in Fig.6-1. (R373 or R374) 2. Turn the POWER switch to ON. 3. Adjust VR301 (VR302) so that the voltage between both sides of R373 (R374) becomes 10mV ± 1mV. 4. Ages for 5 minutes. 5. Adjust VR301 (VR302) so that the voltage between both sides of R373 (R374) becomes 11mV ± 1mV.