ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners, proceed as follows:
� Light the burner. � Turn the knob on the minimum position. � Remove the knob. � With a thin screwdriver, adjust the by-pass screw (see
Fig. 6-10). If changing from natural gas to LPG, completely tighten clockwise the screw, until a small regular flame is obtained. turning the knob from the maximum position to the minimum position.
FO 2100
Fig. 8
� Finally check the flame does not go out when quickly
This procedure can easily be carried out, anyhow the hob has been positioned or built in the working top.