Thank you for having chosen an Electrolux Ergobox� vacuum cleaner. These Operating Instructions cover all Ergobox� models. This means that with your specific model, some accessories/features may not be included. In order to ensure the best results, always use original Electrolux accessories. They have been designed especially for your vacuum cleaner.
� Regularly check that the cable is not damaged. Never use the vacuum cleaner if the cable is damaged. Upholstery: Curtains, lightweight fabrics, etc.: Use the upholstery nozzle (6). Reduce suction power if necessary. Frames, bookshelves, etc.: Use the Easy clean kit* (11). Crevices, corners, etc.: Use the crevice nozzle (5). Store upholstery and crevice nozzle with the clip on the hose handle. Using the turbo nozzle* 20 Adjust the suction power by opening or closing the air vent. B Washable HEPA filter (Ref. No EF75B). Follow steps 22, 23, 24. 26 Turn the washable HEPA filter anticlockwise and pull it away. To put a clean one back, push and turn it clockwise 37* Remove the object(s) and replace the connection hose. 38 To avoid loss of suction power, frequently clean the carpet/hard floor nozzle. The easiest way to clean it is by using the hose handle 21 22 23 24 Cleaning the turbo nozzle* 39 Disconnect the nozzle from the vacuum cleaner tube and remove entangled threads, etc. by snipping them away with scissors. Use the hose handle to clean the nozzle.
All servicing and repairs must be carried out by an authorised Electrolux service centre. Be sure to keep the vacuum cleaner in a dry place.
1
2
3
4
Before starting
Open the front cover on the machine and check that Ergobox and the filters are in place. (See also Replacement of the filter(s).) 12 Insert the hose until the catches click to engage (press the catches to release the hose). 3* Insert the hose into the hose handle until the catches click to engage (press the catches to release the hose). 13 Attach the extension tubes* or telescopic tube* to the hose handle and nozzle by pushing and twisting together. (Twist and pull apart to dismantle.) 14 Extend the electric cable and connect it to the mains. The vacuum cleaner is fitted with a cable winder. Once the electric cable has been extended, it stays in that position. 15 To rewind the cable, give it a slight sharp pull and then release. The cable will then automatically rewind. 16 Power Regulation: Twist the power control to the right to start the vacuum cleaner and increase the suction power. Twist the power control to the left to decrease suction power, and further to the left to turn it off. Adjust suction power by using the suction control on the hose handle 17 Practical parking positions (and at the same time a backsaving feature) when you pause during cleaning or when you carry and store the vacuum cleaner. 18 You can carry the vacuum cleaner using the handle on top or on the lower front edge of the machine. 19 Keep the hose in place while storing the vacuum cleaner by extending ergoshock� and placing it across the hose.
Cleaning the washable HEPA filter
Always make sure that the filter you put in Ergobox is completely dry and clean. It is recommended to wash the HEPA filter each time Ergobox is emptied
26 Turn the washable HEPA filter anticlockwise and pull it away.
Accessories
1* 2* 3** 4 5 6 7 5 6 7 8 8 Telescopic tube Extension tubes Hose handle + hose Carpet/hard floor nozzle Crevice nozzle Upholstery nozzle Accessories clip
Ergobox� (from left to right: front part, HEPA filter, cover) 9* Turbo nozzle 10* Parquet nozzle 11* Easy clean kit
Note: Do not use the turbo nozzle on skin rugs, rugs with long fringes or a pile depth exceeding 15 mm. To avoid damaging the carpet, do not keep the nozzle stationary whilst the brush is rotating. Do not pass the nozzle across electric cables, and be sure to switch off the vacuum cleaner immediately after use.
Troubleshooting
The vacuum cleaner does not start � � � Check that the cable is connected to the mains. Check that the plug and cable are not damaged. Check for a blown fuse.
Wash it with a brush under a tap or wash it in a washing machine (max. temperature 60°). Let the filter dry before putting it back.
25
26
Emptying Ergobox
The more often you empty Ergobox, the less often you will get the filter clogged.
21 The filter clogging indicator turns to red when the filter needs to be cleaned or replaced. 22 Grasp Ergobox and lift it out as shown in the illustration. 23 Place it with the transparent part underneath and pull the yellow catch to remove the metal fastening. 24 Remove the cover (rear part) carefully and empty possible remaining dust. 25 Empty the transparent (front) part.
Putting Ergobox back
Make sure Ergobox and the filters are dry. Make sure the motor filter is in place. (See also Replacement of filter(s).) Make sure the washable HEPA filter is in place. (See also Replacement of filter(s).)
29 Fix the front and rear parts together with the 3 hooks.
The vacuum cleaner stops � Check if Ergobox is full. If so, empty it and clean both the box and the filter before putting it back in the cleaner. Is the nozzle, tube or hose blocked? Are the filters blocked?
Safety precautions
The cleaner should only be used by adults and only for normal vacuuming in a domestic environment. The vacuum cleaner features double insulation and does not need to be earthed. 9 10 11 Never vacuum: � In wet areas. � Close to flammable gases etc. � Without Ergobox to avoid damaging the cleaner. A safety device is fitted, which prevents the cover closing without Ergobox. Do not attempt to force the cover shut. � When housing shows visible signs of damage.
� �
Close the catch by fixing the metal fastening.
30 Put Ergobox back in the cleaner.
Water has entered the vacuum cleaner It will be necessary to replace the motor at an authorised Electrolux service centre. Damage to the motor caused by the penetration of water is not covered by the warranty. 27 28 29 30
Cleaning the hose and nozzle
The vaccum cleaner stops automatically if the nozzle, tube, hose or filters become blocked. In such cases, disconnect from mains and allow to cool for 20-30 minutes. Clear blockage and/or replace filters and restart. Tubes and hoses 33 Use a cleaning strip or similar to clear the tubes and hose. Hose handle could be dismantled from hose if cleaning is needed. 34 It may also be possible to remove the obstruction in the hose by squeezing it. However, be careful in case the obstruction is caused by glass or needles caught inside the hose.
Cleaning Ergobox
After having separated the front and the rear part, and after removing the HEPA filter, wash it under a tap or a shower. It is also possible to wash it in a dish washer. Use of detergent might make Ergobox opaque but this will not affect the efficiency. Make sure it is dry before putting it back.
Consumer information
Electrolux declines all responsibility for damages arising from any improper use of the appliance or in cases of tampering with the appliance. This product is designed with the environment in mind. All plastic parts are marked for recycling purposes. For details see our web site: www.electrolux.com If you have any comments on the cleaner or the Instructions for Use booklet please e-mail us at:
[email protected]
Never vacuum: 12 13 14 15 � � � � Sharp objects. Fluids (this can cause serious damage to the machine). Hot or cold cinders, lit cigarette butts, etc.
31
32
33
34
Replacement of the filter(s)
The more often the better for the efficiency of the cleaner. In standard household use, the filters should be replaced approximately every 3 years. Never use the vacuum cleaner without filter(s).
A Motor-filter (Ref. No. EF 74). 22 Grasp Ergobox and lift it out as shown in the illustration. 27 Pull the filter holder upwards until it comes away from the groove. Carefully pull the old, dirty filter(s) out of the filter holder and replace with a new filter(s). 28 Reinstall the filter holder containing the new filter(s).
Fine dust, for example from plaster, concrete, flour, hot or cold ashes. The above may cause serious damage to the motor � damage which is not covered by the warranty. Electrical cable precautions: � 16 17 � � � A damaged cable should only be replaced by an authorised Electrolux service centre. Damage to the machine�s cable is not covered by the warranty. Never pull or lift the vacuum cleaner by the cable. Disconnect the plug from the mains before cleaning or maintenance of the vacuum cleaner.
Note: The warranty does not cover any damage to the hose caused by cleaning it.
Cleaning the floor nozzle* 35* Press each wheel-hub and draw away the wheels. Use the crevice nozzle to clean the wheel axles. Remove dustballs, hair or other objects that may be entangled. Replace the wheels by pressing them onto the axles. 36* Larger objects can be accessed by removing the connection hose from the nozzle (press the small catches located on each side and simultaneously draw the connection tube outwards in an upright position).
If you cannot find accessories to your Electrolux vacuum cleaner, please visit our website at www.electrolux.co.uk or call 08706 055 055.
Getting the best results
To get the best performance, use the cleaner at full power position. If the power setting is at 50%, then the filter will clog more quickly. Use the nozzles as follows: Carpets: Use the carpet/hard floor nozzle with the lever* in position (31). Reduce suction power for small carpets. Hard floors: Use the carpet/hard floor nozzle with the lever* in position (32). Wooden floors: Use the parquet nozzle* (10).
35
36
37
*Certain models only. **Execution depending on model.
18 19 20
*Certain models only. **Execution depending on model.
38
39
ELX_ergobox_eng_inl.indd 2-5
04-05-19 16.20.08