Su carrito de compras está vacío
|
Productos
|
Información
|
Destacado
|
|
No hay comentarios de productos.
1
2
3
4
2. Receiver (Wireless SP) side
(1) In a case where the power is not turned on (the POWER LED does not light)
A
No power (The POWER LED does not light.)
Insert the FFC correctly.
No
Is the FFC (*1) correctly inserted?
(*1) : FFC between CN5901 (RX Assy) and CN5902 (LED Assy)
Yes
B
Is the POWER LED lit?
No
Yes
Is the fuse FU1 blown?
No
Is the IC11 and/or IC14 in MAIN Assy broken? Yes Replace IC11 and/or IC14.
No
Check that the circuits are not short-circuited. As the circuit for +9 V is most likely to have been shortcircuited, check the circuits around IC15.
Yes Replace the FU1 fuse.
C
Yes
Yes
Is the POWER LED lit?
No
Is the POWER LED lit?
No
Yes Inspection completed.
Yes
(2) In a case where no sound is output
D
No sound
Check the Transmitter side.
No
Is TUNED LED lit? Yes
E
Check the "SP PROTECT"circuits around Q3455 and Q3454.
No
Is the relay on?
Yes
Replace IC12 and IC13.
No
Is +B voltage active?
Yes (A)
F
(B)
36
1 2
XW-HTP550
3 4
|
|
 |
> |
|
|
Parse Time: 0.226 - Number of Queries: 94 - Query Time: 0.045