No hay comentarios de productos.
XVM-H65 SECTION 4 TEST MODE
Setting Method: 1. Turn off power to the connection box XA-113. 2. While holding the TEST switch (S407) down for more than 5 seconds, turn on power to XA-113. Then, release the TEST switch (S407). 3. TEST MODE MENU is indicated.
Ver 1.1
Terminating Method: Select the MENU No. 7, SOFT REST using the MENU key on the remote controller and determine the selection using the INPUT key.
The FOR FACTORY Mode: The FOR FACTORY mode can be used to perform 13 different adjustment items with the remote controller. 1. Select the MENU No. 2, FOR FACTORY using the MENU key on the remote controller and determine the selection using the INPUT key. 2. The FOR FACTORY mode is now entered. The following items are selected in turn by pressing the INPUT key repeatedly.
V Com
Y Gain
Black Limt
White Limt
R SUB BRT
B SUB BRT
R SUB CONT
B SUB CONT
Gamma1
Gamma2
VCO Free
PLL/V Pos
H Pos
3. For each item selected, adjust so that the adjustment value is within the specified value range using the R and r keys on the remote controller. 4. After adjustment, press the MENU key on the remote controller to determine the adjustment value. Press the MENU key once more to change to the next item. 5. After all necessary adjustments are completed, select EXIT using the MENU key on the remote controller and press the INPUT key to display the MENU screen. Then, select No.7, SOFT REST using the MENU key and determine the selection using the INPUT key to terminate the TEST mode.
9
|