Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5344 visitantes y 
2 usuarios online.
Productos
Información
Destacado
Inicio >> PIONEER >> XV-DV535/MLXJ Manual de Servicio
 
 0 artículo(s) en Su carrito 

PIONEER XV-DV535/MLXJ
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del PIONEER XV-DV535/MLXJ Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
1

2

3

4

Protection circuit that activates against a PRTCT ERR error
A

2 When the main power supply becomes LO level because of short-circuit or disconnection of connectors
2 -1 Short-circuit-detection circuit for the amplifier power circuit (VH+[VP+15], VD+5, -12 V [VA-12]) Circuit for shutting the power off when VP+15, VD+5, or VA-12 is short-circuited to ground (GND) 2 -3 Short-circuit-detection circuit for VFDP

D

6CH AMP Assy
VD+5 R108 27k

E

TRADE2 Assy

D

6CH AMP Assy
VD+5

VD+5

VH+ (VP+15) Q101_2/2 D101 (D102)
B E2 (Q103_2/2) B2 C2 C2 E2

Q101_1/2 (Q103_1/2)

E

B
R108 to 27k XPROTECT C (µ-com) Q102_1/2 (Q104_1/2)
E B

R101C (R104) 1k + C101 (C102) 1/50

B
R102 (R105) 10k

Q102_2/2 (Q104_2/2)
B2

to XPROTECT (µ-com) Q115 DTA124EUA Q114 2SD2114K (VW) VA-12

R114 82k R112 1k R113 220k

FL AC2

A

R103 (R106) 10k

R109 820 D105 (D106) VH� (VA�12)

If VFDP is short-circuited to GND, or if the DC electric potential at FL AC1 becomes GND level (in Normal mode: about -27 V) because of a failure in the DC bias circuit of FL AC1, Q114 then Q115 are turned on, and the level of XPROTECT becomes low. � The microcomputer detects the XPROTECT level and shuts the power to the unit off.

* ( )means the wiring No. of VP+15 line.

� In Normal mode, as Q101 (Q103) (E2, B2, C2) and Q102 (Q104) (E2, B2, C2) are on, the voltage at Point A is about 5 V. The voltage at Point B is therefore about the same. As Q101 (Q103) (E, C, B) is off, Q102 (Q104) (E, C, B) is also off.
C

(1) When VH+(VP+15) is short-circuited to GND As the voltage at Point B becomes almost ground potential, and Q101 (Q103) (E, C, B) then Q102 (Q104) (E, C, B) are turned on, the level of XPROTECT becomes low. � The microcomputer detects the XPROTECT level and shuts the power to the unit off. (2) When VH-(VA-12) is short-circuited As the electric potential of VE at Q102 (Q104) (E2, C2, B2) becomes the same as that at VB, Q102 (Q104) (E2, C2, B2) is turned off. Following this, Q101 (Q103) (E2, B2, C2) is turned off, which changes the voltage at Points A and B to a value other than 5 V. Therefore, Q101 (Q103) (E, C, B) then Q102 (Q104) (E, C, B) are turned on, the level of XPROTECT becomes low. (3) When VD+5 is short-circuited The level of the XPROTECT line becomes low. The microcomputer detects the XPROTECT level and shuts the power to the unit off. 2 -2 Short-circuit-detection circuit for the DVD power supply (VP+8)

3 When the FAN connector is disconnected or when rotation of the fan is interrupted

D

6CH AMP Assy
VD+5 VPF+15 R3654 1.8k
C

D

to XPROTECT (µ-com)

R108 27k
C2

D3658 UDZS3.9B
B

A

Q3651_2/2 RN1901

B2

Q3652 DTA124TK R3657 33(1/4W) FAN+ D3655 1SS133 FAN� D3651 1SS133

E2

E

+

R3658 2.2k

Q3651_1/2 C3652 D3657 RN1901 47/50 1SS355 R3655 8.2k Q3654 2SD2144S

D
E

6CH AMP Assy

VD+5 R108 27k

VP+8 D104 1SS355

R3656 22k V-12F

If no fan is connected between FAN+ and FAN-, or when the fan cannot rotate because of a foreign object caught in the blades, the BASE of Q3652 becomes OPEN, and Q3652 and Q3651-1/2 (E, C, B) are turned off. Then Q3651-2/2 (E2, B2, C2) is turned on, and the level of XPROTECT becomes low. � The microcomputer detects the XPROTECT level and shuts the power to the unit off. When FAN+ and FAN- are short-circuited, the electric potential at Point A becomes higher than GND level by the addition of the values at D3656 and D3657. As this value is lower than that at D3658, Q3651 (E, C, B) is turned off, Q3651 (E2, B2, C2) is turned on, and the level of XPROTECT becomes low.

XPROTECT

Q106 DTC124EUA Q107 DTA124EUA TUNER

F

As the TUNER line is fixed to GND level, Q107 is always on. If the level at VP+8 falls to GND level because of short-circuit, etc., Q106 is turned on, and the level of the XPROTECT line becomes low. � The microcomputer detects the XPROTECT level and shuts the power to the unit off.

98
1 2

XV-DV333
3 4

Quizás también quiera comprar

$4.99

XV-DV535/MLXJ PIONEER
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.177 - Number of Queries: 103 - Query Time: 0.039