XV-S100DV
DEBUGGING SCREEN SPECIFICATION FOR THE MECHANISM CONTROLLER
� This specifications is subject to change without notice.
1 Indication Method of The Mechanism Controller Debugging Screen
A debugging screen of the mechanism controller is indicated when pressing the test mode remote control unit [GGF1067] in order of the ESC and CHP/TM buttons. Releace from debugging screen display of the mechanism controller with the ESC button.
2 Screen Layout
3 Indication Contents
1. The error that became the trigger that an error of 2 occurred. There are many cases same as 2. 2. The error number that transferred to the system controller Refer to the error list about contents of error number. 3. Code read in state (it does not support in this unit) When X is indicated, ID or subcode are not able to read in. When X is not indicated, they are able to read in. 4. ID or subcode (it does not support in this unit) Subcode indicates the A time. 5. Inside mode of the mechanism controller when an error of 1 occurred It can indicate to a maximum 10 mode. Indicate it in order of an old mode from the left, and go right, and become a new mode. Indicate only a nest share of the mode. 6. Processing step of inside mode of 5 It can grasp the mode reaching an error and transition of step by watching 5 and 6 and it can specify the occurrence place of most errors. 7. Disk information in the mechanism controller ? : Indistinctness NO : There is no disc DVD 1 : DVD single layer DVD 2 : DVD dual layer CD : CD CDR : CD-R or CD-RW CDR P : PRD of CD-R or CD-RW 8. As a result of 8cm /12cm distinction ? : Indistinctness (undistinction) 8 : 8 cm 12 : 12 cm 9. OEIC gain (it does not support in this unit) H : OEIC HIGH gain L : OEIC LOW gain 10. SGC gain for LD of 780nm It indicates a step using in the mechanism controller inside with a hexadecimal number. Set the gain so that S curve becomes 1.8V (p-p) in disc distinction. 11. SGC gain for LD of 650nm For L0. It indicates a step using in the mechanism controller inside with a hexadecimal number. Set a gain so that S curve becomes 1.8V (p-p) in disc distinction. 12. SGC gain for LD of 650nm For L1. It indicates a step using in the mechanism controller inside with a hexadecimal number. Set a gain so that a S curve becomes 1.8V (p-p) in disc distinction. 13. RF count value for disc distinction RF count value to use the disc distinction. It compares threshold value of 14 and 15 and distinguishes the disc. 14. Disc distinction threshold value (DVD and CD) Threshold value of the disc distinction. Distinguish it from DVD if bigger than this value, and distinguish it from CD if small.
75
|
|
|
> |
|