ELECTRIC ADJUSTMENT
All the MD blocks are adjusted and checked in the test mode. If �No Adjust� is displayed, perform the adjustments of 1 to 3.
1. Temperature Compensation Adjustment
* Normally, do not perform the temperature compensation adjustment. If the adjustment value is extensively different, perform the adjustment as given below in a suitable environment for measuring the correct temperature near the unit. Test point: Check the test point on the display. Tool: Thermometer After the MD test mode starts up, press the STOP button to display �ALL SV OFF�. Press the DISPLAY button to display �TEMP = $**�. Press the PAUSE button to display �T + **C: + 00�. Put the thermometer near the MD mechanism to measure the room temperature. Check the value of the thermometer and press the B.SKIP button and F.SKIP button to adjust until the value is the same as ** on the display. Then press the ENTER button to store the value. After adjustment, press the STOP button to return the display to �ALL SV OFF�. If �No Adjust� appears, perform 1) to 3) and press the ENTER button without changing the adjustment value with the B/F.SKIP buttons.
� � 1) 2) 3) 4) 5) 6)
2. Laser Power Adjustment
� � Test point: Check the test point on the display./Pickup laser output Tool: Laser power meter (meters that can measure up to 10 mW)
2-1. Playback Laser Power Adjustment
1) 2) 3) 4) 5) Press the MD EDIT button in the �ALL SV OFF� state to change the display to �LASER READ�. Press the PAUSE button once to display �LASER = $**�. Set it to �LASER = $11� using the B.SKIP and F.SKIP buttons, and press the ENTER button. Measure the pickup laser output using the laser power meter and adjust it using the B.SKIP button and F.SKIP button so that it is around 0.68 mW. After adjustment, press the STOP button to change the display to �ALL SV OFF�.
2-2. Recording Laser Power Adjustment
1) Press the MD EDIT button three times in the �ALL SV OFF� state to change the display to �LASER WRITE�. 2) Press the PAUSE button once to display �LASER = $**�. 3) Set it to �LASER = $9F� using the B.SKIP and F.SKIP buttons, and press the ENTER button. 4) Measure the pickup laser output using the laser power meter and adjust it so that it is around 0.68 mW. 5) After adjustment, press the STOP button to change the display to �ALL SV OFF�. Note: If the laser output exceeds 7.0 mW, the pickup may be damaged.
3. Automatic Sequence Adjustment (EFB/IVR/FOCUS AGC/TRACKING AGC adjustment)
� � Test point: Check the test point on the display. Test disk: MDW-74, TGYS-1 or equivalent
3-1. Adjusting the MO Disk
1) 2) 3) 4) Load the MDW-74. Press the MD MODE button to display �SELECT GRV�. Press the MD function button to display �AUTO ADJ�. After adjustment, �DONE� is displayed. (If the adjustment failed, �FAILED� appears.) Then, press the STOP button to return the display to �ALL SV OFF�.
3-2. IVR, EFB, Focus/ Tracking/ Sled Gain Check of MO Disk
1) 2) 3) 4) Move the pickup to the center of the disk using the B.SKIP button and F.SKIP button. Press the PLAY button to display �FOCUS ON!�. Press the ENTER button to display �ALL SV ON�. Press the STOP button and press the DISPLAY button twice. Confirm that the values of �IV$**:EF$��� are within the range shown below. (hexadecimal) IV$ �**� .......... 03 to 07 EF$ ���� ....... 09 to 12