No hay comentarios de productos.
Alignment and Adjustment
5-3 Head Switching Point Adjustment
1) Playback the alignment tape. 2) Intermittently short-circuit the two test points on Main PCB to set the adjustment mode. (See Fig. 5-2) 3) Press the �SP/SLP� button of remote control then adjustment is operated automatically. (See Fig. 5-1) 4) Turn the Power off.
5-4 NVRAM Option Setting
1) NVRAM Option is adjusted at production line basically. 2) In case Micom (IC601) and NVRAM (IC603 ; EEPROM) is replaced, be sure to set the corresponding ooption number of the repaired model. (If the option is not set, the unit is not operated.) 1) Intermittently short-circuit the two test points on Main PCB to set the adjustment mode. (See Fig. 5-2) 2) Press the �PROG.� button of remote control about 5 seconds then option setting display is appeared. (See Fig. 5-17) 3) Select the option number (See Table 5-2) of corresponding model with �FF� and �REW� button of remote control. 4) If selecting the option number is completed, press the �PLAY� button of remote control. (If �PLAY� button is pressed, the selected number is changes reversed color. ; See Fig. 5-17) 5) Press the �ENTER� button of remote control again to store the option number. (�SAVE� is displayed for a second as shown Fig. 5-18 this setting is completed.) 6) Turn the Power off.
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
ENTER : SAVE
Fig. 5-17 <Table 5-2>
MODEL W-603 TYPE A B C D E F G H OPTION NUMBER 2, 3, 6, 8, 9, 12, 16 2, 3, 6, 8, 9, 12 2, 2, 2, 2, 3, 3, 3, 3, 6, 6, 6, 6, 8, 8, 9, 9, 12, 16 12 12, 16 12
ENTER : SAVE
Fig. 5-18 How to identify the Type Type A B C D E F G H Assy-Cylinder ALPS � � SEM Capstan Motor Sankyo � � � � � � � � � � � � � SEM VR501 Be � � � � None �
2, 3, 6, 12, 16 2, 3, 6, 12
� � � �
Toshiba
5-9