No hay comentarios de productos.
VSX-C300
7.1.2 Protection of the Amplifier Line
1. Detection of abnormalities in DC circuits
This detection has priority over the overload detection and abnormality detection for the fan and thermistor.
If an abnormality has been detected, AMUTE is on, RELAY is off, and the "AMP ERR" display is flashing.
�
Does the abnormality continue for 5 seconds or more?
� Yes
Power is turned off.
� No (recovery)
The program restarts from the beginning.
2. Detection of overload
This detection has priority over the abnormality detection of the fan and thermistor. If an abnormality has been detected, AMUTE is on, RELAY is off, and the "OVERLOAD" display is flashing.
�
Does the abnormality continue for 5 seconds or more?
� Yes
Power is turned off.
� No (recovery)
Power is turned off even if the unit has achieved recovery.
While the unit is recovering from the abnormality, the "OVERLOAD" display continues flashing.
52
|