3. Connect extention cable between the camera for PV-VM202 and the battery adaptor. 4. Turn power on the camera for PV-VM202 and set below function in the MENU. FLASH: ON (MENU => RECORDING SET UP => FLASH : ON) RED EYE REDUCTION : OFF (MENU => RECORDING SET UP => RED EYE REDUCTION : OFF) 5. Set 100cm between the grayed reflection sheet and camera. 6. Shoot it until full screen on the monitor LCD by zooming. 7. Press still button to take still picture. After flash, Picture must be stopped. 8. Connect AV cable to AV OUT/PHONES terminal and confirm the shot VIDEO level on the ocilloscope. 9. It should be �1.5 +- 0.1 V� as Fig. E2. 10. If not, adjust VR7001 and repeat procedure 7-9 again until 1.5 +- 0.1 V.