6. Error Messages
A message may appear while you are adjusting the video camera/recorder. If a message appears, refer to the following table and take appropriate corrective action.
6.1 Error Messages of Adjustment (Camera Adjustment)
ERROR MESSAGE ERROR OCCURRED. IRIS TROUBLE PRESS ANY KEY COUNTERMEASURE Check whether or not power is supplied. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the iris block and replace it if necessary. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in theabove circuit. Check the values in the hall amp circuit and its peripheral circuits. Defective soldering, damage to pattern, etc. in the above circuits. The adjustment program (file) cannot be found. Check the adjustment floppy disk and replace it if necessary. The adjustment program (file) does not start. Check the adjustment floppy disk and replace it if necessary. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box. Supply power again and re-adjust. The subject is too dark. Check the light box. Move the camera closer to the light box. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. The subject is too bright. Move the camera further away from the light box. The subject is too bright or too dark. Check the light box. Move the camera closer to or away from the light box. Supply power again and re-adjust.
ERROR OCCURRED ON da� ADJUSTMENT PRESS ANY KEY D RANGE OVER. ERROR ON da� ADJUSTMENT PRESS ANY KEY. ERROR OCCURRED ON da0 and da1 ADJUSTMENT PRESS ANY KEY FILE NOT FOUND !!!! PRESS ANY KEY FILE OPEN ERROR !!!! PRESS ANY KEY ERROR OCCURRED ON C DUTY ADJUSTMENT PRESS ANY KEY ERROR OCCURRED ON FDET ADJUSTMENT PRESS ANY KEY ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY D RANGE OVER ERROR ON HALL AMP IRIS CANNOT OPEN ANY MORE PRESS ANY KEY
STAURATION ERROR. TOO BRIGHT PRESS ANY KEY CAN'T ADJUST WHITE BALANCE PLEASE RETRY PRESS ANY KEY
3 - 16
|
|
|
> |
|