5 Preparation for 6-2-2-3~6-2-2-9; set up the camera signal adjustment mode. (Write 00 to the address 1FE.)
6-2-2-3.
Before starting these adjustments, set up the auto focus adjust. � Sync level adjustment Measuring instrument Oscilloscope Subject Tape Test point Adjustment address Adjustment level Anything � VIDEO OUT (Terminated in 75�) 1FE 286mVp-p
Video
SYNC 286mVp-p 1H
1) Connect the oscilloscope to the VIDEO-OUT. Adjust the sync level to 286mVp-p.
6-2-2-9.
� Auto white balance adjustment Measuring instrument Subject Tape Test point Adjustment address Adjustment level Vector scope Gray scale � VIDEO OUT (Terminated in 75 �) R-OUT DOOR 016 B-OUT DOOR 018 R-OUT DOOR; 0 ± 3 % B-OUT DOOR; 0 ± 3 %
R-Y Spot
B-Y Center point
1) Attach the color temperature conversion filter (JIGHOYA-LB165) to the front of the lens. 2) Using the addresses R-OUT DOOR 016 and B-OUT DOOR 018, adjust the spot to the center. 3) Take off the color temperature conversion filter. 5 Write FF to the address 1FE to the address 1FE to exit the camera adjustment mode.