|
Usuarios conectados
Actualmente hay 6043 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
UX-S10H/IT 3. Diagnostic items description 3. 1. Soft switch mode
Used to change the soft switch settings. The soft switch which is stored internally is set by using the keys. The available soft switches are SW-A1 to SW-O6. The content of soft switches is shown in page 2-5 to 2-19. The contents are set to factory default settings.
3. 6. Signal send mode
This mode is used to send various signals to the circuit during FAX communication. Every push of START key sends a signal in the following sequence. Moreover, the signal sound is also output to the speaker when the line monitor of the soft switch is on. [1] No signals (CML signal turn on) [2] 14400BPS (V.33) [3] 12000BPS (V.33) [4] 14400BPS (V.17) [5] 12000BPS (V.17) [6] 9600BPS (V.17) [7] 7200BPS (V.17) [8] 9600BPS (V.29) [9] 7200BPS (V.29) [10] 4800BPS (V27ter) [11] 2400BPS (V27ter) [12] 300BPS (FLAG) [13] 2100Hz (CED) [14] 1100Hz (CNG) [15] 1300Hz (V.23 MARK) [16] 2100Hz (V.23 SPACE) [17] PSEUDO RINGER
3. 2. ROM & RAM check
ROM executes the sum check, and RAM executes the matching test. The result will be notified with the number of short sounds of the buzzer as well as by printing the ROM & RAM check list. Number of short sounds of buzzer 0 � No error 1 � ROM error 2 � RAM error (4 Kbyte SRAM or 512 Kbyte DRAM)
3. 3. Aging mode
If any document is present, copying will be executed sheet by sheet. If no document is present, the check pattern will be printed sheet by sheet. This operation will be executed at a rate of one sheet per 5 minutes, and will be ended at a total of 10 sheets.
3. 4. Panel key test
This mode is used to check whether each key operates properly. Press the key on the operation panel, and the key will be displayed on the display. Therefore, press all keys. At this time, finally press the STOP key. When the STOP key is pressed, the keys which are not judged as "pressed" will be printed on the result list. � LED part of the contact image sensor (CIS) is kept on during the term from when "START" of the panel test mode to end with the STOP key.
3. 7. Memory clear
This mode is used to clear the backup memory and reset to the default settings.
3. 8. Shading mode
The mode is used for the shading compensation. For reading, set up the special original paper. The compensation memorizes the reference data of white and black for reading. Moreover, the memorized data is not erased even if memory clear mode is executed.
3. 5. Check pattern
This mode is used to check the state of the printing head. It is ended with the following pattern printed on one printing sheet. White/Black(3/8 mm alternately) >>> About 30 mm long. All Black >>> About 30 mm long All White >>> From All Black end to Pin OFF End White >>> From Pin OFF to 16.5 mm long
1 2 3 4
3. 9. All black print
LETTER: 216 mm LEGAL: 216 mm A4: 210 mm Void area 4 mm
This mode is used to check the state of the printing head and to intentionally overheat it. Whole dots are printed over the interval of 2 m. If it is overheated or the printing sheet is jammed, press STOP key for the end.
3. 10. Auto feeder mode
In this mode, a document is inserted and discharged to check the auto feed function. After this mode is started, set a document, and the document feed will be automatically tested.
1 2 3
3. 11. Message print
In this mode, all the message data, which are used for displaying indication and list print, are printed as a contrast table of the selected language and English.
3. 12. Flash memory check
Data is written into and read from the flash memory to check data conformity. When the unit enters this mode, the check is started.
4
Pin off 16.5 mm
2�3
|
|
|
> |
|