1. AM TRACKING VOLTAGE ADJUSTMENTS
DC VOLTMETER ........................... CONNECT TO TEST POINT P5 and GND
NO. 1 2
P5
Band AM AM
Frequency 530KHz 1720KHz
Adjust for 2.2V 9.5V
Adjustment T1 TVC1
GND
2. AM RF ADJUSTMENT
Signal Generator ........................ Connects to the AM ANT. Coil through the loop antenna. Adjust for the indication of VTVM of the wave form of scope to be maximum. BAND Step 1 AM 2 3 Frequency 630KHz 1420KHz Adjust for Maximum sensitivity Maximum sensitivity Repeat steps 1 and 2 several times. Adjustment L2, T2 TVC2
3. FM 19kHz REJECTION ADJUSTMENT
NO. 1 2 3 Frequency 97.8MHz 97.8MHz 97.8MHz Adjust for L rejection R rejection L, R rejection Adjustment T4 T5 TVR3