1. Azimuth Adjustment Settings: F � Test tape: TTA-330 � Test point: EARPHONE JACK (J103) � Adjustment location: Azimuth adjustment screw � PAUSE: OFF Method: G 2. Tape Speed Adjustment (4.8 cm/s) Settings: � Test tape: TTA-100 (TAPE CENTER) � Test point: EARPHONE JACK (J103) � Adjustment location: VR202 H � PAUSE: OFF � VOLUME: Maximum � PLAYBACK SPEED: Normal (Speed volume center) Method: I Play back the test tape, and adjust for 3000 Hz ±10Hz � VOLUME: Maximum. Play back the test tape, and adjust so that the output (8 kHz) becomes maximum.