Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5853 visitantes online.
Productos
Información
Destacado
Inicio >> NAD >> T973 Manual de Servicio
 
 0 artículo(s) en Su carrito 

NAD T973
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del NAD T973 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
ALIGNMENT PROCEDURE (T973)
A. DC OFFSET VOLTAGE The DC OFFSET between OFFSET Test Point and AGND must be controlled within 0+/-3mV. If it�s found to be out of this range, change the TL084BCD to get it meet the requirement. B. IDLING CURRENT The idling current at the final stage of the unit should be set to about 40mA+/-10mA. Adjust RV102 (As marked as �Idling Current ADJ� in the enclosed drawing below) to control the voltage between Idling current Test point 1 and 2 to be 8mV +/- 2mV. Preheat the unit for 10 to 15 minutes, and then readjust to 8mV +/- 2mV. (Please note: The idling current must be adjusted when all modules are assembled into the unit.) C. ISC SENSITIVITY Adjust Pot RV104 (as marked as �ISC SENS ADJ� in the below drawing) to get the voltage across �ISC SENS TEST POINT� and AGND to be 0mV+/-10mV. (Please note that the ISC should be adjusted when all modules are assembled into the unit. It�s not possible to get 0V +/-10mV if the modules are not assembled. D. THERMAL SENSE ADJUSTMENT The adjustment should be always done when the T973 is cool condition. (That means the temperature inside the unit should be almost same as the ambient temperature. Connector P208B that connects the transformer and power board should be removed to avoid that the Idling current to heat up the unit excessively) At ambient temperature of 25 C degree and when the unit is just turned on (still in cool condition), adjust the pot RV103 (as marked as �THERMAL SENS ADJ� in the below drawing) to get voltage across the THERMAL TEST POINT and AGND to be 750mV +/-10mV. While the ambient temperature is different, the voltage will vary as well. There is a relation between the temperature and voltage, that is; if the ambient temperature is 20 degree C, the voltage should be 850mV+/-10mV; if the ambient temperature is 30 degree C, the voltage should be adjusted to 650mV+/-10mV, etc. E. Fan Cut Off Point Adjustment Note: This Fan cut off function does not appear on PCB V10.0, V11.0 or MKII version but only appeared on PCB V12.0. Run the unit for all 7 channels at 1 kHz, 4ohms load, and 250mW output. Do this adjustment when the unit heats up, for example; run the unit at all 7 channels at 50W/4ohms for 10 minutes. Then adjust Pot RV201 on power supply board so the voltage at Pin14 of IC203 just changes from negative to positive (to get the fans just start turning). Then turn off the input signal and monitor if fans will stop within 30 seconds, then turn on the input signal again to see if the fans start turning immediately.