5-3 HEAD SWITCHING POINT ADJUSTMENT
1) Playback the alignment tape. 2) Press the �TEST� button on Main PCB/Function PCB to set the adjustment mode. (See Fig. 5-2 and 5-3) 3) Press the �SP/LP� button of remote control then adjustment is operated automatically. (See Fig. 5-1) 4) Turn the Power off.
5-4 NVRAM OPTION SETTING
1) NVRAM Option is adjusted at production line basically. 2) In case Micom (IC601) and NVRAM (IC605 ; EEPROM) is replaced, be sure to set the corresponding option number of the reqaired model. (If the option is not set, the unit is not operated.) 1) Press the �TEST� button on Main PCB/Function PCB to set the adjustment mode. (See Fig. 5-2 and 5-3) 2) Press the �MENU� button on the remote control about 5 seconds then option setting display is appeared. (See Fig. 5-5 and 5-6) 3) Select the option number (See Table 5-1) of corresponding model with �FF/REW/STOP/PAUSE� button on the remote control. 4) If selecting the option number is completed, press the �OK (PLAY)� button of remote control. (If �OK (PLAY)� button is pressed, the selected number is changes reversed color. ; See Fig. 5-5) 5) Press the �MENU� button of remote control again to store the option number. (�PLEASE WAIT� is displayed for a second as shown Fig. 5-6 and this setting is completed.) 6) Turn the Power off.