SF-S55N 3) Set the hole position of two lead cams as shown below. L. Adjusting the stapler unit home position 1) Loosen the two screws (1), and move ahead the flag plate to adjust the home position of stapler unit.
4)
Holding the state of Step 3) above, put the belt (4) on the gear, return the flange (1) to its original position, and fix it with the E-ring (2).
J. Adjusting the tensioner 1) Loosen the tensioner fixing screw (1), and then tighten the tensioner fixing screw (1) in the position where the tensioner 2 (2) is stopped by the tension of spring (3). 2)
(Before removing the flag plate mark the fixing position.)
Make an adjustment so that the staple is located as shown below when corner stapling is performed.
K. Adjusting the tension of stapler unit shift drive belt 1) Loosen the tensioner fixing screw (1), and then tighten the tensioner fixing screw (1) in the place where the tensioner (2) is stopped by the tension of spring (3).