No hay comentarios de productos.
file:///E:/SEHD/OT/SE-HD501V/SVC/s0200000000x.html
2 Before Repair and Adjustment
TOP PREVIOUS NEXT 1. Turn off the power supply. Using a 10Ω , 10W resistor, connect both ends of power supply capacitors (C102-105, 127) in order to discharge the voltage. 2. Before turning the power supply on, after completion of repair, slowly apply the primary voltage by using a power supply voltage controller to make sure that the consumed current at 50/60 Hz in NO SIGNAL mode should be shown below withrespect to supply voltage 220 V240 V.
Area Power supply voltage (GC) AC 220-240V (GK) AC 220V
Consumed current 50 Hz 50/60 Hz 50-150 mA 50 Hz 50-150 mA
�@ TOP PREVIOUS NEXT
file:///E:/SEHD/OT/SE-HD501V/SVC/s0200000000x.html [2006-09-11 14:34:58]
|