SCD-333A SECTION 1 DIAGRAMS
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS. for printed wiring boards: � X : parts extracted from the component side. � Y : parts extracted from the conductor side. � z : Through hole. � b : Pattern from the side which enables seeing. (The other layer�s patterns are not indicated.) Caution: Pattern face side: Parts on the pattern face side seen from the (Side B) pattern face are indicated. Parts face side: Parts on the parts face side seen from the (Side A) parts face are indicated. for schematic diagram: � All capacitors are in µF unless otherwise noted. pF: µµF 50 WV or less are not indicated except for electrolytics and tantalums. � All resistors are in � and 1/4 W or less unless otherwise specified. � % : indicates tolerance. � f : internal component. Note: The components identified by mark 0 or dotted line with mark 0 are critical for safety. Replace only with part number specified. � U : B+ Line. � Signal path. J : CD
TP032