The gas safety shutoff must be tested after the refrigerator is connected to LP gas supply. To test the gas safety shutoff, proceed as follows:
A. Start the refrigerator according to the instructions for LP Gas Operation. See "sec. 5.2 Using the refrigerator� Check that the gas flame is lit. Allow it to burn a few minutes to ensure a full, stable flame. C. Turn the gas safety valve (B, FIG. 8) to the "OFF" position. Within 1-2 minutes the gas safety device within the valve should automatically close. An audible "click" from the valve may be heard. D. Turn the gas safety valve to the "HIGH" position (B, FIG. 8). E. Without pushing in the knob (B, FIG. 8) of the gas safety device, apply a commercial leak detection solution to the burner jet. No bubbles should appear. Bubbles indicate a gas leak and the safety valve must be replaced by a qualified service personnel. F. Rinse the burner jet with water. Light the burner and allow it to burn for five minutes.
! WARNING
DO NOT USE A FLAME TO CHECK FOR GAS LEAKS
Gas pressure
Category
mbar BE DK DE FI FR GR IE IS IT LU NL NO AT PT SE CH ES UK X X X X X X X X X X X X X X X X X X X X X X X