COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
MONITORED LATCH SWITCH, MONITOR SWITCH AND STOP SWITCH REMOVAL
1. CARRY OUT 3D CHECKS. 2. Remove the control panel assembly referring to "CONTROL PANEL ASSEMBLY REMOVAL". 3. Disconnect the leads from all switches. 4. Remove the two (2) screws holding the latch hook to the oven cavity. 5. Remove the latch hook. 6. Remove the switch(es) from the latch hook by pushing the retaining tab backwards slightly and turning the switch(es) on the post. 7. Now the switch(es) is free.
Post
SW2: Stop switch
SW3: Monitor switch Tab Post SW1: Monitored latch switch
Figure C-5. Switches
MONITORED LATCH SWITCH, STOP SWITCH AND MONITOR SWITCH ADJUSTMENT
If the monitored latch switch, stop switch and monitor switch do not operate properly due to a mis-adjustment, the following adjustment should be made. 1. CARRY OUT 3D CHECKS. 2. Loosen the two (2) screws holding the latch hook to the oven cavity front flange. 3. With the door closed, adjust the latch hook by moving it back and forward or up and down. In and out play of the door allowed by the latch hook should be less than 0.5 mm. The horizontal position of the latch hook should be placed where the monitor switch has activated with the door closed. The vertical position of the latch hook should be placed where the monitored latch switch and stop switch have activated with the door closed. 4. Secure the screws with washers firmly. 5. Make sure that all switches operate. If the latch head has not pushed the plungers of the monitor switch with door closed, adjust the latch hook position. At that time, the latch head should have pushed the plungers of the monitored latch switch and stop switch. If the latch head has not pushed the plungers of the monitored latch switch and stop switch with door closed, loose two (2) screws holding latch hook to oven cavity front flange and adjust the latch hook position.
2. The contacts (COM-NO) of the stop switch and the monitored latch switch open within 1.8mm gap between right side of cavity face plate and door when door is opened. 3. When the door is closed, the contacts (COM-NO) of the stop switch close. 4. When the door is closed the contacts (COM-NC) of the monitor switch and monitored latch switch open. And the contacts (COM-NO) of their switches close. 5. Re-install outer case and check for microwave leakage around the door with an approved microwave survey meter. (Refer to Microwave Measurement Procedure.)
Door
Latch hook Latch Heads Tab SW2: Stop switch
After adjustment, make sure of following:
1. In and out play of door remains less than 0.5 mm when latched position. First check the latch hook position, pushing and pulling upper portion of the door toward the oven face. Then check the lower latch hook position, pushing and pulling lower portion of the door toward the oven face. Both results (play of the door) should be less than 0.5mm.
SW1: Monitored latch switch
SW3: Monitor switch
Figure C-6 Latch Switches Adjustment
R-775(W)R-785(AL) - 30
|
|
|
> |
|