The unit turns on and off too much,.or
Check if ... The air conditioner is not properly sized for your room. The filter is dirty or obstructed by debris. The inside evaporator and outside condenser coils are dirty or obstructed by debris. There is excessive heat or moisture (open container cooking, showers, etc.) in the room. The louvers are blocked. The outside temperature is below 65°F (18%). The temperature of the room you are trying to cool is extremely hot. Windows or doors to the outside are open. Then ...
does not cool room
Check the cooling capabilities of your room air conditioner. Room air conditioners are not designed to cool multiple rooms. Clean the filter. See page 14. Clean the inside evaporator and outside condenser coils. See page 18.
Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing appliances during the hottest part of the day.
Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc. Do not try to operate your air conditioner when the outside temperature is below 65°F (18°C). Allow extra time for the air conditioner to cool off a very hot room. I Close all windows and doors.
I I
The Air or Exhaust Control is Set the Air or Exhaust Control to OFF/CLOSED for maximum cooling. set to FRESH AIR/EXHAUST/ OPEN (on some models). The Thermostat is not at a cool enough setting. The air conditioner is installed on the sunny side of your house. Adjust the Thermostat to a cooler setting by turning the knob clockwise. Turn Fan Control to HIGH. Install your air conditioner in a more shaded window. I
Water drips from cabinet
Check if ... The air conditioner is not properly leveled. The air conditioner should slope slightly downward toward the outside.
into your house
Then ... Level the air conditioner to provide a %� downward slope toward the outside (l/2bubble on a carpenter�s level [or 1.l degrees]) to ensure proper drainage. See the Installation Instructions for an illustration. Reposition or shim the cabinet as necessary. NOTE: Do NOT drill a hole in the bottom of the metal base and condensate pan.