Replacing the Projection Lamp
CAUTION: � Potential hazard of glass particles if lamp has ruptured. Please have Sharp Authorized LCD Projector Dealer or Service Center replace lamp if rupture occurs. � Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before removing the lamp cage. The rated lamp life is about 1000 hours. The rated lamp life is the average life of the lamps produced and tested (under the test conditions of our company). However, it may become shorter depending on the conditions of usage. After the lamp has been operating for 1000 hours or longer, the STATUS indicator on the control panel will light and the �LAMP USAGE� icon which shows hours of total lamp usage will be displayed on the screen. When this happens, turn off the unit and replace the lamp cage with a new one. The unit will not turn on after 1100 hours. (It will go off if it is in use.)
Removing and installing the lamp unit
CAUTION
� Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of the projector. � Do not loosen any screws except for those mentioned in the instructions below. There is danger of electric shock. � To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
1
Turn off the power.
2
Disconnect the power cord.
3
Open the lamp cage cover.
Press the POWER ON/OFF button. Wait until the cooling fan stops.
ON/OFF
FOCU S
PG-M10X
Unplug the power cord from the AC socket. Wait at least one hour after power cord is disconnected.
Turn over the projector and unfasten the user service screw that secures the lamp cage cover. Then open the cover in the direction of the arrow.
User service screw
MOUSE MENU VIDEO R-CLICK/UNDO
4
Remove the lamp cage.
Unfasten the three securing screws on the lamp cage. Hold the lamp cage by the handle and pull it upward.
Securing screws
� Reset the lamp usage timer after replacing the lamp. See page 29 for information.
� When the lamp usage timer reaches 1100 hours, it becomes impossible to turn on the power and menus are not displayed. In such a case, see �When the lamp usage timer has exceeds 1100 hours and the unit will not turn on� on page 29. � Obtain a replacement lamp cage at the store where the unit was purchased. Please specify the following information when ordering a replacement lamp cartridge: � Model name : BQC-PGM10X//-1
OPEN
POWER
ON/OFF
STATUS
INPUT SELECT
AUTO SYNC
or
ON/OFF
ON/OFF COMPUTER
DIGITAL MULTIMEDIA PROJECTOR
5
Replace the lamp cage (after changing the lamp).
6
Close the lamp cage cover.
Press the lamp cage firmly into the lamp cage compartment. Fasten the securing screws.
Close the lamp cage cover in the direction of the arrow. Then fasten the user service screw.
User service screw