|
Usuarios conectados
Actualmente hay 6024 visitantes y 5 usuarios online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
PDP-R03E
6. ADJUSTMENT
� Procedure for turning ON the power
1. Connecting the system � Using the system cable, connect the plasma display and the media receiver. � Connect the plasma display to the AC power source. � Connect the media receiver to the AC power source. 2. Procedure for turning ON the power � Turn ON the AC power switch located on the plasma display. The power indicator on the plasma display will start blinking in red. (When the AC power switch on the media receiver is not ON, the power indicator on the plasma display always blinks in red.) � Turn ON the power switch located on the media receiver. The power indicator on the media receiver will be illuminated in green. Simultaneously, the power indicator on the plasma display will change from blinking in red to illumination in green. Now the system has started up. � If the power indicator on the media receiver is illuminated in red, press the 10 key located on the remote controller and the STANDBY/ON button located on the plasma display. The power indicators on the plasma display and the media receiver will change from red to green. Now the system has started up.
� Procedure for adjusting each part of media receiver
� The adjustments were made to the best settings at factory. If any setting deviates or if any readjustment is regarded as necessary when any part is replaced, perform the following steps. � Any parameter that has been changed within the process adjustment is stored on the memory. If any readjustment is required, write down the current value before changing it. 1. Preparation for adjustment � Use a stable AC power source. � If the program is upgraded, it will take approximately 1 minute for the EEPROM to be initialized before any video appears. Therefore, you will need to wait for this time period. Do not turn OFF the power or operate the system during the period. � If the program is rewritten, write down the parameters that have been changed within the process adjustment (see �5.OSD menu and parameters displayed at manual adjustment), initialize the EEPROM, and then reenter the recorded values. 2. Procedure for upgrading the software (1) With the power being OFF, open the top cabinet for the media receiver and then set the slide switch from the NORMAL position to the WRITE position by inserting a needle-like insulator into the cutout located between the WHITE port on the rear of the shield case for the I/F board and the RS-232C port. (2) Connect the PC having the program installed, to the media receiver using the cross cable for the RS-232C port (for the details of the program, see Appendix). (3) Open the MS-DOS window on the PC and then go to the directory in which the software is installed. (4) Start up the system to which the media receiver and plasma display have been connected. (5) Run �vup.bat at the MS-DOS prompt. The software will be upgraded. (6) Load the file �civic_XXXa.bhx/main.bhx/osd.bhx�. It will take approximately 7 minutes until the file has been loaded. Never turn OFF the power or operate the system during this rewriting period. (7) After the file has been loaded, turn OFF the plasma display and the media receiver and then return the slide switch in the above step 1 from the WRITE position to the NORMAL position. Now the software has been upgraded.
96
|
|
|
> |
|