Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 21 (Red 1023+). / [MKR S21]
A
Set VOL YNOFSA D to the tentative setting value 103. / [VYF 103]
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Display RST MASK 22 (Green 1023+). / [MKR S22]
Yes
To the Recovery flowchart (2-1)
B
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-2)
C
Display RST MASK 15 (Magenta 120). / [MKR S15]
Set VOL YNOFSA D to the tentative setting value 151. / [VYF 151]
Is there erroneous discharge (abnormal lit cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-3)
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
D
Determine the tentative setting value for VOL YNOFSA D as the final value.
From the Recovery flowchart (2-2) and (2-3)
[Adjustment completed]
E
Note: Make sure that the following values become the final setting values. VOL SUS *1 VOL XPOSF2 *1 VOL OFFSET VOL YNOFS1 D *1 VOL RST P *1 VOL YNOFS3 D *1 VOL XPOFS1 *1 VOL YNOFS4 D *1 VOL YNOFS4 A *1: The tentative setting value becomes the final value.
F