Inicio >>
PIONEER >>
PDP-LX5090H/WYS7 Manual de Servicio
0 artículo(s) en Su carrito
Opiniones de los clientes
No hay comentarios de productos.
TEXT_PDF_SNIPPET
1
2
3
4
A
Recovery flowchart (1-1)...Changing the VOL OFFSET setting
[From the Main flowchart (1)]
RST MASK 09 (Pink)
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 101 or less.
B
Current VOL OFFSET > 096?
Yes
Replacement of abnormal circuits or re-replacement of the panel required
No Display RST MASK 18 (Red 626). / [MKR S18]
C
Set VOL OFFSET to the current setting value plus 123. / [VOF ���]
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Display RST MASK 19 (Green 626). / [MKR S19]
Yes
Replacement of abnormal circuits or re-replacement of the panel required
D
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Set VOL OFFSET to the current setting value minus 78. / [VOF ���]
Yes
Replacement of abnormal circuits or re-replacement of the panel required
Determine the current VOL OFFSET setting value as the final value.