2 Actual Vofs adjustment (1)
A
(From 1 )
(Check Vofs_max1 with the red 760 signal.) Perform aging with RST MASK 01 (white) displayed for 3 seconds: MKS S51
Set to RST MASK 17 (pale purple).
MKS S67
Set VOL OFFSET to 024 (15 [V] ).
B
VOF 024
Are there any dark cells? Yes Gradually increase Vofs data VOF ��� until dark cells disappear (Vofs should be 255 (60 [V]) or less).
No
Set Vofs_min1 to 024 (15 [V]).
Note: This setting value becomes the value for Vofs_min1.
Vofs_min1
[STEP]
Note: Take note of the value for Vofs_min1.
Is Vofs_min1 144 (38 [V]) or smaller?
C
No
Replace the panel again or abnormality in circuits
Yes
Return the Vofs value to the tentative voltage setting.
VOF ���
Note: for checking the lower limit of Vofs accurately. This is
(Check Vofs_min2 with the sky color signal.) Perform aging with RST MASK 01 (white) displayed for 3 seconds: MKS S51
D
Set to RST MASK 16 (sky color).
MKS S66
Set VOL OFFSET to 024 (15 [V] ).
VOF 024
Are there any dark cells? Yes Gradually increase the Vofs data until dark cells disappear (Vofs should be 255 (60 [V]) or less).
E
No
Set Vofs_min2 to 024 (15 [V]).
VOF ���
Note: This setting value becomes the value for Vofs_min2.
Vofs_min2
[STEP]
Note: Take note of the value
Is Vofs_min2 144 (38 [V]) or smaller? Yes
No
Replace the panel again or abnormality in circuits
for Vofs_min2.
Return the Vofs value to the tentative voltage setting.
Note: This is for checking the lower limit of Vofs accurately.
F
(To 3 )
124
1 2
PDP-6071PU
3 4
|
|
 |
> |
|