NW-HD3 SECTION 4 TEST MODE
1. OUTLINE For the LCD display, the LCD on the main unit is shown, but the contents of LCD display on the remote commander are same. Operation in the test mode is performed with the main unit. A key having no particular description in the text, indicates a main unit key. Power supply voltage Volume SOUND EQ AVLS [HOLD] switch Set states : 3.65 to 3.75 V : 27 : OFF : OFF : OFF : horizontal states 5. OPERATION OF THE TEST MODE 5-1. Power 5-1-1. Power supply voltage check This mode is used in case power supply voltage in the state where all power supply lines (1.2 V/1.5 V/1.8 V/2.0 V/2.4 V/3.3 V/VSTBY/ VDC) are starting is checked. Checking method: 1. Enter the test mode. 2. Press the , key to display major item, and press the M m key to select the �POWER�.
LCD display
2. SETTING THE TEST MODE 1. Supply power to the set. 2. Switch-on the [HOLD] switch on the main unit. 3. Operate as follows. � When use only main unit While pressing the [MODE] key on the main unit, press the key on the main unit as following order. >�>�.�.�>�.�>�. �M�m � When use the main unit and remote commander While pressing the [MODE] key on the main unit, press the key on the remote commander as following order. >�>�.�.�>�.�>�. � +� � 4. Switch-off the [HOLD] switch on the main unit and enter the test mode. 3. RELEASING THE TEST MODE Press the [MENU] key on the main unit or x key on the remote commander for 1.5 seconds or more, turn off the power and release the test mode. 4. CONFIGURATION OF THE TEST MODE Flow of the test mode:
F/W version display
, key < key
POWER
3. Press the , key to display minor item, and press the M m key to select the �V CHK�.
LCD display
V CHK
4. Press the Bx key, �START� is displayed and all power supply lines are started.
LCD display
START
5. Press the [MODE] key, �HD ON� or �HD OFF� is displayed. In this state, each time [MODE] key is pressed, hard disk drive power supply ON/OFF switch is performed.
LCD display
HD ON
6. Press the [MENU] key, return to minor item selection screen. 5-1-2. Consumption current (read state) check This mode is used in case consumption current (read state) in the state where the hard disk drive has booted is checked. Checking method: 1. Enter the test mode. 2. Press the , key to display major item, and press the M m key to select the �POWER�.
LCD display
Major item
, key < key
Major item switching: M m key
POWER
3. Press the , key to display minor item, and press the M m key to select the �A RD�.
LCD display
Minor item
Bx key
Minor item switching: M m key
A RD
4. Press the Bx key, �READY?� is displayed. In this state, each time [MODE] key is pressed, EL back light ON/OFF switch is performed.
LCD display
Start Automatic Finish or Result
READY?
[MENU] key
9
|
|
|
> |
|