Discharging the high voltage capacitors WARNING There is high voltage present with high current capabilities in the circuits of the primary and secondary windings, choke coil and heat sinkof the inverter. It is extremely dangerous to work on or near these circuits with the oven energized. DO NOT measure the voltage in the high voltage circuit including the filament voltage of the magnetron. WARNING Never touch any circuit wiring with your hand or with an insulated tool during operation.
2.6.
Confirm after repair
1. After repair or replacement of parts, make sure that the screws of the oven, etc. are neither loosen or missing. Microwave might leak if screws are not properly tightened. 2. Make sure that all electrical connections are tight before inserting the plug into the wall outlet. 3. Check for microwave energy leakage. (Refer to procedure for measuring microwave energy leakage). CAUTION MICROWAVE RADIATION USE CAUTION NOT TO BECOME EXPOSED TO RADIATION FROM THE MICROWAVE MAGNETRON OR OTHER PARTS CONDUCTING MICROWAVE ENERGY. IMPORTANT NOTICE The following components have potentials above 2000V while the appliance is operated. � Magnetron � High voltage transformer (Located on inverter (U)) � High voltage diodes (Located on inverter (U)) � High voltage capacitors (Located on inverter (U)) Pay special attention to these areas. When the appliance is operated with the door hinges or magnetron installed incorrectly, the microwave leakage can exceed more than 5mW/cm 2. After repair or exchange, it is very important to check if the magnetron and the door hinges are correctly installed.
2.3.
Part replacement.
When any part or component is to be replaced, always ensure that the power cord is removed from the wall outlet.
2.4.
When the 20A fuse is blown due to the operation of the short switch:
WARNING When the 20A 120V fuse is blown due to the operation of the interlock monitor switch, replace all of the components (primary latch switch, short switch and power relay B (RY1)). 1. This is mandatory. Refer to �adjustments and measurements� for the location of these switches. 2. When replacing the fuse, confirm that it has the appropriate rating for these models. 3. When replacing faulty switches, be sure the mounting tabs are not bent, broken or deficient in their ability to hold the switches.
2.7.
Caution
Sharp edges
2.5.
Avoid inserting nails, wire etc. through any holes in the unit during operation.
Please use caution when unpacking, installing or moving the unit, as some exposed edges may be sharp to the touch and cause injury if not handled with care.
Never insert a wire, nail or any other metal object through the lamp holes on the cavity or any holes or gaps, because such objects may work as an antennaand cause microwave leakage.