Power Supply Adjustment Auto Item Feed
Note: This mode is available to perform the temperature correction and power supply adjustment without entering the manual mode.
� Setting method of power supply adjustment auto item feed mode. 1. Set the test mode (see page 13) 2. Press the . key or press the [VOL --] key to activate the T overall adjustment mode.
Remote commander LCD display
5. Connect digital voltmeter to the measuring points on the MAIN board, and adjust the voltage with the [VOL +] or [VOL --] key. (see page 18 to 21) Press the X key to write the adjusted value, and the item number increases automatically. 6. When not writing the adjusted value, press the > key to t move to the next item. The . key is available to back to the T last item. 7. The following message is displayed after all power supply adjustments finish.
Remote commander LCD display
000 A s s y
**: Adjusted value
**
000 A D J
OK
3. Press the [END SEARCH] key or [P MODE] key on the remote commander to set the temperature correction mode.
Remote commander LCD display
8. Press the xCANCEL/CHG key to return the test mode (display check mode).
015 S e t T m p * *
4. To change the initial value (hexadecimal) adjust with the [VOL +] or [VOL --] key. Press the X key to write the adjusted value, and the item number increases automatically. When not writing the adjusted value, press the > key to t move to the next item.
Remote commander LCD display
741 V C 1 L * *
� Configuration of power supply adjustment auto item feed
000Assy ** END SEARCH key or P MODE key on the remote commander. 015 SetTmp 19
> . .