1-1-3. Discharging of the Flashlight Power Supply The capacitor which is used as power supply of flashlight is charged with 200 V to 300 V voltage. Discharge this voltage before starting adjustments in order to protect service engineers from electric shock during adjustment. Discharge procedure 1. Press the FLASH button (PK-52/50 board S705) and turn off the FLASH LED (PK-52/50 board D701). 2. Fabricate the discharging jig as shown in Fig. 5-1-4 locally by yourself. Connect the discharging jig to the positive (+) and negative (�) terminal of the flash voltage charge capacitor. Allow ten seconds to discharge the voltage.