MD-MT180
How to remove the Lift motor (See Fig. 11-1.)
1. Remove the solder joints (D1) x 2 of the lift motor lead wire. 2. Remove the screw (D2) x 1 pc., and remove the lift motor. Note: Take care so that the motor gear is not damaged. (If the gear is damaged, noise is caused.)
Lift Motor SolderJoints (D1)x2
How to reinstall the optical pickup (See Fig. 11-2.)
1. Remove the screw (E1) x 1 pc., and remove the spring. 2. Slowly raise the optical pickup.
(D2) x1 ø1.4 x5mm
Figure 11-1
Optical Pickup Unit (E1) x1 ø1.7 x3.5mm
Spring
Figure 11-2