ELECTRICAL ADJUSTMENTS
2-4: WHITE BALANCE NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2-8: VERTICAL LINEARITY NOTE: Adjust after performing adjustments in section 2-7. After the adjustment of Vertical Linearity, reconfirm the Vertical Position and Vertical Size adjustments. 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (09) on the remote control to select "VLIN". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on upside and downside becomes minimum. 2-9: SEPARATION Please do the method (1) or method (2) adjustment. Method (1) 1. Set the multi-sound signal generator for each different Lch and R-ch frequency (Ex. L-ch=2KHz, R-ch=400Hz) 2. 3. 4. and receive the RF signal. Connect the oscilloscope to the Audio Out Jack. Press the AUDIO button on the remote control to set to the stereo mode. Activate the adjustment mode display of Fig. 1-1 and press the channel button (64) on the remote control to select �SEPAL�. Press the VOL. UP/DOWN button on the remote control to adjust it until the audio output wave becomes a fine sine wave. Press the CH UP button 1 time to set to "SEPAH" mode. Press the VOL. UP/DOWN button on the remote control to adjust it until the audio output wave becomes a fine sine wave.
2. Receive the gray scale pattern from the Pattern Generator. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (16) on the remote control to select "G DRV". 5. Press the CH. UP/DOWN button on the remote control to select the "R CUT", "G CUT", "B CUT", "R DRV" or "B DRV". 6. Adjust the VOL. UP/DOWN button on the remote control to whiten the R CUT, G CUT, B CUT, R DRV, and B DRV at each step tone sections equally. 7. Perform the above adjustments 5 and 6 until the white color is looked like a white. 2-5: HORIZONTAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (04) on the remote control to select "HPOSI". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-6: VERTICAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (08) on the remote control to select "VPOSI". 4. Check if the step No. V POSI is "02". 5. Adjust the VR401 until the horizontal line becomes fit to notch of the shadow mask. 2-7: VERTICAL SIZE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (07) on the remote control to select "VSIZE". 4. Press the VOL. UP/DOWN button on the remote control until the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 5. Receive a broadcast and check if the picture is normal.
5.
6. 7.
Method (2) 1. Set the multi-sound signal generator L-ch=1KHz, R-ch =Non input and receive the RF signal. 2. Connect the oscilloscope to the Audio Out Jack (R-ch). 3. Press the AUDIO button on the remote control to set to the stereo mode. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (64) on the remote control to select �SEPAL�. 5. Press the VOL. UP/DOWN button on the remote control to adjust it until the R-ch output becomes minimum. 6. Press the CH UP button 1 time to set to "SEPAH" mode. 7. Press the VOL. UP/DOWN button on the remote control to adjust it until the R-ch output becomes minimum. 8. Set the multi-sound signal generator L-ch=Non input, R-ch=1KHz and receive the RF signal. 9. Connect the oscilloscope to the Audio Out Jack (L-ch). Then perform the above adjustments 3~7.
D-2
|
|
|
> |
|