* Eine MD mit der Beschriftung nach oben in Pfeilrichtung in den MD-Recorder einschieben.
DISPLAY
2
INPUT A D1 D2
Protect Recordings from Accidental Erasure
b a c You can make your MDs impossible to be recorded on by sliding the record-protect tab on the MDs to open the record-protect hole. To make the MDs recordable again, return the record-protect tab.
Check the Contents of Recording Immediately
Immediately after recording is stopped, press the n button. The playback of the recording starts from where the recording was started. To playback from the beginning of the MD, immediately after recording is stopped, press the e button again. Then, press the n button to start playback. If you have left the MD-121 unused since recording has stopped, both the playing track number indication in the track number display and that in the time display should be flashing. Pressing the PLAY button in this state causes the track whose track number indicators are flashing to play.
Storage Period of Backup Data
The recorded contents will be backed up inside the MD-121 even if the MD recorder�s power cord is accidentally unplugged or if a power failure occurs before they are stored to the disc (when TOC is lit) or when they are being stored to the disc (when TOC is flashing). You can restore the data which was backed up during such an accident or power failure by pressing the STAND-BY/ON button after plugging in the power cord or immediately after the power failure is solved. Note, however, that the period in which the backup data is stored is approx. only 2 weeks. So, especially after a power failure, perform the above procedures as soon as possible after power is restored.