1. When re-connecting lead wires to ON/OFF switch make sure the insulated lead is reconnected to its original location as shown.
1. Refer to Handle Assembly Replacement Section. 2. With handle removed from body disassemble handle by removing fourteen (14) screws. Refer to Handle Assembly Exploded View. 3. Remove handle release button and spring. 4. Remove damaged cord.
3.8.2.
Installation
1. Replace damaged cord. carefully routing power cord as illustrated. 2. Reinstall handle as outlined in the handle installation section. 3. Replace the cord stopper, the two (2) cord stopper screws and the wire connectors. NOTE: Never reuse a cord stopper. Always install a new cord stopper whenever the old one is removed. NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the vacuum cleaner should be reassembled and checked for dielectric breakdown or current leakage.
3.9.
3.9.1.
ON/OFF Switch Replacement
Removal
1. Remove the dust cover to expose the electrical connections of the ON/OFF switch.
2. Remove the insulated black wire lead from switch. Note the location of the insulated lead when removing from switch. 3. Remove uninsulated black wire from switch. 4. Remove the ON/OFF switch, (for ON/OFF switch replacement) by depressing the switch retaining tabs while pushing up out of the dust compartment at the same time.