Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 6043 visitantes online.
Productos
Información
Destacado
Inicio >> PIONEER >> M-AX10 Manual de Servicio
 
 0 artículo(s) en Su carrito 

PIONEER M-AX10
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del PIONEER M-AX10 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
M-AX10

3.1 Key Inputs
A key input becomes valid after 40 ms, to eliminate chatter. The ATT.THROUGH key input from OFF to ON becomes valid when the key is held pressed for 2 seconds.

Port 16 (SPRYH)(Pin16) is set to "L" 10 ms after ATT.THROUGH switching signal input, and relay is set to OFF. After another 30 ms, the INDICATOR port is processed. Port 31 (FMT)(Pin31) is set to "H," and muting is set to ON. Switching process is performed 100 ms after ATT.THROUGH switching signal input. When switching ATT THROUGH from ON to OFF: Data transfer to the DAC IC is performed 2 seconds after the key input. When switching ATT.THROUGH from OFF to ON: Port 2 (LD), port 3 (CLK), and port 4 (SRD) are fixed to "L" before DACVR (pin 13) is set to "L," 30 ms after relay becomes OFF. (See "6. DAC Volume Transfer."(P.49))

3.2 Switch inputs
The MODE switch (rotary switch) setting is read when the power is turned on. The switch operation with POWER ON is invalid. (See "7. WARNING."(P.50))

4. KEY PROCESSING (IC901)
4.1 ATT.THROUGH Switching
The ATT.THROUGH key input from ON to OFF becomes valid when the key is held pressed for 2 seconds. Any other key input during these 2 seconds is invalid. When switching from OFF to ON, the key input becomes valid at normal timing. After another 2 seconds, port 31 (FMT)(Pin31) is set to "L," and muting is set to OFF. After another 3 seconds, port 16 (SPRYH)(Pin16) is set to "H," and relay becomes OFF.

Key input valid

EEPROM writing

1
Relay

2 10 msec 3 5 sec
Mute

4 40 msec 5
LED ON/OFF processing 2 sec

6 40 msec

Switching

7
100 msec VOL. processing (ON � OFF)

8 2 sec
VOL. data line processing (OFF � ON)

9
Silent processing

0 200 msec
Fig.2 Timing chart when ATT. through key is pressed

47

Quizás también quiera comprar

$4.99

M-AX10 PIONEER
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.186 - Number of Queries: 100 - Query Time: 0.046