4. Remove one screw and the Exposure Lamp Thermal Fuse Holder. * When the Exposure Lamp Thermal Fuse Holder cannot be removed easily, unplug the Connector of the right-hand side Exposure Lamp Terminal.
1132D057
5. Remove two screws from the Exposure Lamp Thermal Fuse Holder and remove the Exposure Lamp Thermal Fuse.
ATTENTION Make sure that thermofuse is in contact with the fuse holder and the lamp reflector.
1132D058
2-12. Removal of the Ozone Filter
1. Switch on the copier and pull out the cassette. 2. Depress the Start Key. When the Scanner comes near the bottom of the Original Scale, turn off the Power Switch.
3. Remove the Original Cover, Top Cover and Original Glass. 4. Remove two screws and the Ozone Filter Cover.
5. Lift the left-hand side of the Ozone Filter and slide the Ozone Filter to the left to remove.