5. ADJUSTING PROCEDURE OF EACH SECTION
5-6. Service Adjusting
5-6-2. AV input Adjustment
conditions Adjustment method
8 Tint adjustment Input standard colour bar signal 1. Adjust N358 TINT so as to get the
(N358) (the same pattern as that of JPNcolour bar signal magenta amplitude
8CH) of N358 into AV1. equal to 2.0Vp-p.
2. Connect the oscilloscope to TP820
(B output).
15 Tint adjustment Input standard colour bar signal 1. Adjust PAL TINT so as to get the
(PAL) (the same pattern as that of E-12CH) colour bar signal magenta amplitude
of PAL into AV1. equal to 2.0Vp-p.
2. Connect the oscilloscope to TP820
(B output).
3
20 Tint adjustment Input standard colour bar signal 1. Adjust SECAM TINT so as to get the
(SECAM) (the same pattern as that of E-10CH) colour bar signal magenta amplitude
of SECAM into AV1. equal to 2.0Vp-p.
2. Connect the oscilloscope to TP820
(B output).
LC-121M2H LC-150M2H
|
|
 |
> |
|
|