Making the appliance level
The four feet of the appliance are pre-adjusted. Large degrees of unevenness can be compensated for by individually adjusting the height adjustable screw feet. Use the special spanner supplied to do this. Important! Do not use pieces of wood, cardboard or such like to level out unevenness in the floor, but adjust the height adjustable screw feet instead.
Electrical connection
Details about the voltage, type of supply and the fuses required are to be found on the rating plate. The rating plate is next to the doorway.
Connecting to the water supply
Important! � This appliance must not be connected to the hot water system. � When connecting it, use only new hose kits. � Only connect the appliance to the drinking water supply. Rain water or water for industrial use may only be used if it fulfils the requirements of DIN1986 and DIN1988. � Do not kink or crush the water inlet hose or drain hose.
Permitted water pressure
The water pressure must be at least 1bar (=10N/cm2 =0.1MPa) and may be a maximum of 10bar (=100N/cm2 =1MPa). � If more than 10bar: Connect a pressure reduction valve. � If less than 1bar: Disconnect the appliance end of the inlet hose from the solenoid inlet valve and remove the flow meter. (In addition remove the filter using pointed pliers and take out the rubber gasket behind it.) Re-insert the filter.