|
Usuarios conectados
Actualmente hay 6042 visitantes y 1 usuarios online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
1 3-2. CONVERGENCE 1
Preparation :
l
0 Tilt the V.STAT magnet and adjust the static convergence by opening or closing the V.STAT magnet.
Before starting this adjustment, adjust the focus, horizontal size, and vertical size. Minimize the brightness setting. Provide dot pattern. Horizontal and Vertical Static Convergence
l l
(1)
Center dot
4.
If the V.STAT magnet is moved in the direction of the @ and @ arrows, the red, green, and blue points move as shown below.
V. STAT Magnet 14 H. STAT I A
R RV 701 H. STAT RV 708 (G 2) SCREEN
G
B
1.
(Moving horizontally), adjust the HSTAT control so that the red, green, and blue points are on top of each other at the center of the screen.
2.
(Moving vertically), adjust the V.STAT magnet so that the red, green, and blue points are on top of each other at the center of the screen.
0
3.
If the H.STAT variable resistor cannot bring the red, green, and blue points together at the center of the screen, adjust the horizontal convergence with the H.STAT variable resistor and the V. STAT magnet in the manner given below. (In this case, the H.STAT variable resistor and the V.STAT magnet influence each other)
-25-
|
|
|
> |
|