Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 6043 visitantes online.
Productos
Información
Destacado
Inicio >> KENWOOD >> KAC819 Manual de Servicio
 
 0 artículo(s) en Su carrito 

KENWOOD KAC819
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del KENWOOD KAC819 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
KAC-819
CIRCUIT DESCRIPTION
SP P-CON Switching Circuit
When the SP output from the head unit is connected to SP IN, the power can be switched ON/OFF based on the DC voltage of the SP output. However, As certain haed unit models output DC permanently or generate a click during switching OFF, it is required to provide the capability of previous P-CON switching. A circuit which can perform the switching without using a switch is described below. This circuit performs switching by inhibiting the operation of the S-P-CON circuit when a voltage is applied to the P-CON pin.

Circuit operation description
When the head unit is connected to SP-IN, the DC component in the SP output turns Q38 ON through D32 and R158. When a voltage is applied to the P-CON pin under this condition, Q45 is turned ON via R188, positive feedback is applied by combination of Q45 and Q46, Q45 and Q46 are held at ON, so the voltage at point (A) is almost 0V and the SP-P-CON circuit is not activated. This circuit holds the ON status while the DC voltage from SP is present. Therefore, in this condition, the P-CON circuit continues functioning. To cancel the functioning, the voltage at the SP-IN pin should go 0V.
R188 100K

D29
to P-CON terminal 7.5V power control

D32
from SP-P-CON

A
10u35

+

R158
3.3K

Q38

Q46

4.7K

Q45

ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS TUNER (RECEIVER) SETTINGS ALIGNMENT POINTS ALIGN FOR FIG.

Connect a cassette receiver or other receiver.
IDEL CURRENT Connect a DC voltmeter to CN3 VR3 After sufficient aging adjust to 2mV

1

-

Volume : 0

-

2

Quizás también quiera comprar

$4.99

KAC-819 KENWOOD
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.138 - Number of Queries: 103 - Query Time: 0.034