|
Usuarios conectados
Actualmente hay 5726 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
1-2(E) JTC-P200/JTA-SB200
Owner�s Record
The model and serial numbers are located on the rear. Record these numbers in the spaces provided below. Refer to them whenever you call upon your Sony dealer regarding this product. Model No. ______________ Serial No. _______________
Overview
For JTC-P200 Attention � when the product is installed in a rack:
� Elevated operating ambient temperature If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer�s maximum rated ambient temperature of 0 to 45°C (Tmra). � Reduced air flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. � Mechanical loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. � Circuit overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. � Reliable earthing Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips).
JTC-P200 ICU
The ICU (Image Control Unit) is the main unit for controlling the images on the JumboTron screen. Connect the image sources to the ICU, and control with the JTC-C200 ICU controller and JME-SA200 screen alignment controller. For details, refer to the Operation Manual of the JTC -C200 ICU controller.
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. For the customers in the U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
JTA-LS200 ABC Sensor Unit
The ABC (Automatic Brightness Control) sensor unit is used for the automatic adjustment of the brightness of the screen. Connect the ABC sensor unit to the JTC-P200 ICU to detect the ambient light. For details, refer to the Operation Manual of the JTC-C200 ICU controller.
4
Table of contents
|
|
|
> |
|