DISASSEMBLY ADVICE CAPS OPERATION KNOBS 1 SWITCH KNOB 2 THERMOSTAT KNOB 3 SWITCH 4 THERMOSTAT 5 PILOT LIGHT 9
remove SCREW A (4x) remove FRONT PART 101 remove CAPS OPERATION KNOBS 2
PARTS LIST HD 3271 / HD 3272 / HD 3273 STAND 102 POS. 1 2 3 4 5 6 7 8 9
NOTE: For standardisation reasons, only the red-coloured operation knobs have been incorporated into this manual. The grey coloured knobs have to be replaced by the red-coloured ones. When a cordset has to be replaced, always use a cordset with core wires with a diameter of 1.0 mm2. Parts, with numbers from 100 upwards, cannot be ordered separatly.
DESCRIPTION CAP OPERATION KNOBS SWITCH KNOB THERMOSTAT KNOB SWITCH THERMOSTAT HEATING ELEMENT MOTOR FAN BLADE PILOT LAMP
remove SCREW A 4x remove FRONT PLATE 101 remove SCREW B 2x
3 L 2
1000 W
FAN BLADE 8
1
1000 W S P. L. M
remove SCREW A 4x remove FRONT PLATE 101
N T C. O.
L N T C. O.
= LINE = NEUTRE = THERMOSTAT (Not included in HD3271) = CUT OUT
P. L. = PILOT LIGHT (Not included in HD3271) S = SWITCH M = MOTOR DAP0244
NOTE: AFTER THE PRODUCT HAS BEEN REPAIRED, IT SHOULD FUNCTION PROPERLY AND HAS TO MEET THE SAFETY REQUIREMENTS AND LEGAL REGULATIONS AS LAID DOWN AND OFFICIALLY ESTABLISHED AT THIS MOMENT. Possible complaints The heater doesn�t function : 1) When set to the cool air setting action: Set the thermostat knob to the highest position. 2) The overheating safety device has been activated action: To reset the overheating device, remove the mains plug from the wall socket and let the heater cool down for 30 minutes.