HCD-NEZ30 SECTION 5 MECHANICAL ADJUSTMENTS
CD POWER MANEGE This mode is for switch the CD power supply on/off. Even if this state pulls out AC plug, it is held. Procedure: 1. Press the I/1 button to turn the power on. 2. Set the FUNCTION to CD. 3. Press the I/1 button again to turn the power off (standby). 4. While pressing the CD u button, press the I/1 button. 5. If turns power on and display �CD POWER�, then display �ON� or �OFF�. � Precaution 1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, appiy suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. � Torque Measurement
Mode FWD Torque Meter CQ-102C Meter Reading 2.95 � 6.86 mN�m (30 � 70 g�cm) (0.42 � 0.97 oz�inch) 0.15 � 5.39 mN�m (1.5 � 5.5 g�cm) (0.021 � 0.076 oz�inch) more than 5.89 mN�m (more than 60 g�cm) (more than 0.83 oz�inch) more than 5.89 mN�m (more than 60 g�cm) (more than 0.83 oz�inch)
FWD Back Tension
CQ-102C
FF
CQ-201B
REW
CQ-201B
� Tape Tension Measurement
Mode FWD Tension Meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz)