EN 22 5.4
5.4.1
5.
DVD 620 /0X1
Diagnostic Software Descriptions and Troubleshooting
The test can be left by pressing the PLAY key for more than one second. 5.4.3 Sound 2 Test The second soundtest is performed by producing a sine sound (nucleus AudioSineOn). The signal can be stopped by pressing the STOP key. The display will show the following message:
Mono PCB Digital Part
Picture Test The picture test is performed by putting a predefined picture (colour bar) on the display (nucleus VideoColDencOn), and asking the user for confirmation. The display will show the following message:
CL 96532065_015.eps 100102
CL 96532065_019.eps 100102
Figure 5-18 Figure 5-21 By pressing OPEN/CLOSE the user confirms the test, pressing STOP will indicate the picture was invisible or incorrect. Pressing PLAY will proceed to the next test. If the user presses PLAY without pressing OPEN/CLOSE or STOP first, the result of this test will be TRUE (picture ok). Note: The colour bar must be simultaneously available on the CVBS, YC, and RGB (or YUV) outputs available. On the SCART only the CVBS and RGB signals will be available. 5.4.2 Sound 1 & SCART DVD Test The first soundtest is performed by starting a pink noise sound that needs confirmation from the user (nucleus AudioPinkNoiseOn). The display will show the following message: After the audio signal has been stopped, by pressing OPEN/CLOSE, the user confirms the test. Pressing STOP will indicate that something went wrong. Pressing PLAY will proceed to the next. If the user presses PLAY without pressing OPEN/CLOSE or STOP first, the result of this test will be TRUE (sound ok).
CL 16532162_038.eps 080102
Figure 5-19 On the TV screen a colour bar (generated by nucleus VideoColDencOn) is visible and the internally generated pinknoise is audible. By pressing the PLAY key, the user confirms the test. Pressing the STOP key will indicate the sound was inaudible or incorrect. Note: Only for double scart models, SCART loop-through will be simultaneously active during this test. SCART loop-through will be measured with the aid of an external video source. By pressing the PLAY key, there will be switched over to the external source. This must become now visible on the TV srcreen (using the SCART). The local display will show the following message:
CL 16532162_039.eps 080102
Figure 5-20 The internally generated colour bar is still available on the CVBS and Y/C outputs. And the pinknoise-signal is still available on the cinch audio outputs. By pressing the OPEN/CLOSE button, the internal generated colour bar becomes visual again.
|
|
|
> |
|